The intensity of radiation I at a point 0 within dS is then defined as. The spread of cancer cells from the place where they first formed to another part of.
20kVm Typical RF magnetic induction.
High rf frequency protocol plasma. The Independent Cancer Research Foundations High RF Frequency Research Protocol implements the use of a specially designed frequency generator to produce specific resonant frequencies which are applied to the body via a broadcast method using a plasma ray tube antenna or by using a contact method using four electrodes which come in contact with the body. The High RF Frequency Generator with Plasma Amplifier is based on the Rife Machine technology of the 1930s and 1940s. Rife designed his frequency generators to kill microbes which were inside of the cancer cells.
His carrier wave was designed to get the other frequencies past the cell membrane to get to the microbes. What this device adds to the Cellect-Budwig protocol in. The Plasma-Beck Protocol 1 The Barefoot Calcium Protocol.
The spread of cancer cells from the place where they first formed to another part of. 2 Six Lemons a Day Alkaline. This protocol is based on the theory that an alkaline environment is the.
The high frequency produces the plasma and the low frequency controls the ion distribution in the sheath. These devices are quite different from the original RIEs because they operate at high pressure 10100mtorr and the gaps are very small 13cm. Radiofrequency plasmas rf plasmas are formed in a flow of gas by an externally applied radio frequency field.
103141 Inductively coupled plasmas ICP In inductively coupled plasmas inductively coupled rf plasmas or inductively coupled argon plasmas energy transfer to the gas is achieved with the help of an induction coil or. Ion flux and ion energy. High frequency f h to control plasma density ion flux while low frequency f l to control ion energy and its specter IED f h 27-162 MHz f l 2-1356 sometime both 2 and 1356 MHz to tailor IED Today Dual Triple Frequency CCPs are.
PLASMA RADIO WAVES let dS be a small area drawn perpendicular to r. DP is the power in the radian frequency interval between co and codc flowing through dS in the direction r within the truncated cone of solid angle dQ. The intensity of radiation I at a point 0 within dS is then defined as.
I dPdSdcod. To a fair approximation the high frequency power controls the plasma density due to the more efficient displacement current and sheath heating mechanisms mentioned above. The low frequency excitation influences the peak ion bombardment energy section 32.
Therefore the user has some ability to independently adjust the ion bombardment energy and the plasma density which is. Even for a relatively high-gas pressure of 50 Pa used in RF PECVD however the plasma density at a conventional driving frequency of 1356 MHz is less than 10 10 cm 3. In order to increase the plasma density at the typical frequency of 1356 MHz ingenious device is required.
By admin in treatments. There are hundreds of alternative cancer treatments. However less than two dozen of these protocols are strong enough to give advanced cancer patients real hope for survival.
These we call Stage IV protocols or primary protocols. This protocol is essentially the Dirt Cheap Protocol with a required High RF Frequency Protocol Plasma Amplifier plus the Bob Beck Protocol which is recommended but not required. The Dirt Cheap Protocol article is kept up-to-date far better than this article so it is advisable to use the Dirt Cheap Protocol rather than this article.
The High RF Frequency Protocol Plasma is required. Distance to the plasma 5cm to the wall 20cm Typical RF electric field. 20kVm Typical RF magnetic induction.
10-3T BRF 10-3 T B03 T. RF electric field 20 kVm. The High RF Frequency Generator and Plasma Tube Amplifier.
For cancer patients who have not had a lot of chemotherapy and radiation and have at least 4 months to live they can start with this protocol. Either way the Understanding Treating Cancer article can help you understand what to do about buying time and dealing with cachexia. This protocol is essentially.
It is now generally accepted that the frequency ω2π at which a high frequency HF discharge is excited has considerable influence on the properties of the plasma. For example the electron density n obtained for a given HF power density P A in the plasma is usually higher at microwave MW than at radio frequencies. This in turn strongly affects the outcome of a given plasma process for example.
It has been established that higher-frequency plasma such as VHF plasma switches the direction of electron acceleration between two electrodes more rapidly than lower-frequency plasma so that the rate of collision with gas molecules is increased leading to an increased ionization rate. High-power plasma power supply is very useful for many industrial and medical applications. Plasma is generated artificially in the laboratory or industry by applying the electric or magnetic field.
In this manuscript we presented the simple 4T analog MOS control high voltage high frequency inverter circuit as a plasma power supply using modulation index technique. A high frequency Modulation. The process of superimposing a low frequency signal onto a high frequency signal Three modulation schemes available.
The amplitude of the carrier varies in accordance to the information signal 2Frequency Modulation FM. The frequency of the carrier varies in. High frequency HF is the ITU designation for the range of radio frequency electromagnetic waves radio waves between 3 and 30 megahertz MHz.
It is also known as the decameter band or decameter wave as its wavelengths range from one to ten decameters ten to one hundred meters. Frequencies immediately below HF are denoted medium frequency MF while the next band of higher frequencies.